What the Cold Spring Harbor report found
The report, as Lou wrote it up.
2019, a colonial, about 26 years old: 6 items flagged: 2 roof, chimney and attic; 2 exterior; 1 garage. As recorded: gable roof, architectural and asphalt/fiberglass, seen from: walked, framed with 2 x 8 rafters; attic: attic hatch in bedroom closet, r-19 or better insulation, ridge vents, soffit vents and passive ventilation; clapboard wood siding, chimney: brick; poured concrete foundation, 2 x 10 and 4"x 8" x 2 steel i beams floor framing, steel lally columns; hydronic heat on natural gas, hot water off the boiler; 200-amp circuit breakers (General Electric and Murray), romex wiring, copper supply pipes, public water, air conditioner unit; double-hung, thermal/insulated and casement windows, hardwood t&g, carpet and tile floors, wood cabinets, granite counters. Flagged, in Lou’s words: “Recessed lighting fixtures in attic are a source of drafts”; “Clapboard was not trimmed to soffit fascia board, leaving voids under fascia at peaks on three sides of house”; “Void under trim left front”; “Rear glass sliding door lock, needs an adjustment, will not lock”; “Front stoop pavers need "OO" sand to fill in the joints”; “Front stoop left front has open joint”; “Left rear wooden stoop hand rail is loose, end post is rotted”; “Left rear wooden stoop, side fascia board is dry-rotted”; “Rear center wooden stoop end posts are dry rotted at bottom”; “Safety Item with pool in yard: Right side gate latch needs to be adjusted to lock”; “Safety Item: Door is steel but hollow, not fire rated”; “Both oven doors are full of cooking grease”. Also noted: “Brick chimney and cement cap is in good condition”; “Asphalt driveway has spider cracks and a hole from a container”; “Jacuzzi bath is GFCI protected to outlet at bottom behind entrance”; “Jacuzzi access panel is located in attic through master closet access”; “Fixture outside shower, bulb will not unscrew”; “Left side exterior wall near gas meter”; “No paper towels, wipes or long hair allowed in pump or pump will clog”; “Gem box to right of main panel, cover is missing”; “Fireplace converted to gas burning”; “GFCI outlet on side of pool panel does not trip”; “Inside of pool panel is rusted because door latch is broken”. On the day: 87°F, hot and humid, damp ground, no rain in the three days before; the house faces west. Not present in this house: chemicals for pool capable of being stored with a lock; does pool have any rescue equipment; pool heaters; range hood; solid fuel heating devices; trash compactor; vapor retarders; ventilation fans and thermostatic controls.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Suffolk County page · What an inspection costs · Schedule an inspection.