What the Blue Point report found
The report, as Lou wrote it up.
2020, a contemporary, about 35 years old, a condominium: 9 items flagged: 3 roof, chimney and attic; 3 exterior; 2 kitchen. As recorded: gable roof, architectural and asphalt/fiberglass, seen from: ground, framed with 2 x 12 rafters; attic: storage, fiberglass, below and r-19 insulation, soffit vents and passive ventilation; clapboard vinyl siding, chimney: vinyl siding; poured concrete foundation, 2 x 10 and 2"x 10"x 3ea main wood beam floor framing, steel screw jacks and supporting walls, crawlspace: crawled; electric heat heat on electric, 50 gallon x 2 electric water heater (exterior utility closet left front); 200-amp circuit breakers (Cutler Hammer), romex wiring, copper supply pipes, public water, geothermal; casement and thermal/insulated windows, hardwood t&g, carpet and tile floors, laminate cabinets, granite counters. Flagged, in Lou’s words: “Upper leader pipe over front entrance needs to be extended down to lower gutter”; “Upper leader pipe over garage needs to be extended down to lower gutter”; “Loose insulation batts piled on floor in front attic, taking up storage space”; “Unable to open attic hatch in master closet”; “Front, exterior utility closet door is water damaged on inside”; “Trex board on balcony is cracked and raised causing trip hazard”; “Left front corner of glass stove cooktop is broken and won't heat up”; “Right front bedroom door frame is out of square”; “Right front casement window crank is loose”; “Rug on floor in front bedroom closet is not new and doesn't match other rugs”; “Rug in first floor closet is not new and doesn't match new rugs in house”; “Ceramic Tile on floor in shower are cracked”; “First floor, left side fireplace glass door lower hinge is broken”. Also noted: “Inspected roof from ground, too windy to attempt ladder inspection”; “Left front of crawl space”; “Main and sub panels in exterior utility closet to left of front entrance”; “Geo thermal pipes thru left side foundation wall in crawl space”. On the day: 44°F, clear, windy, damp ground, rain in the three days before; the house faces west. Not present in this house: basement windows; burner; chimneys, flues and vents; combustion air; fence; food waste disposer; fuel storage and distribution systems; gas meter; gas/lp firelogs and fireplaces; instant hot water; main fuel shut off; range hood; sewage ejection pump; trash compactor; vapor retarders; ventilation fans and thermostatic controls.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Suffolk County page · What an inspection costs · Schedule an inspection.