What the Fire Island Pines reports found
Lou’s two summaries flagged 16 items Repair or Replace, most for the exterior (6), roof, chimney and attic (4) and pool (3). Each report, newest first, as Lou wrote it up.
2022, a colonial, about 61 years old: 4 items flagged: 1 roof, chimney and attic; 1 kitchen; 1 structure. As recorded: flat roof, asphalt/fiberglass, seen from: walked roof; attic: no storage, soffit vents ventilation; verticle slats t & g wood siding, chimney: metal flue pipe; wood post foundation, 2 x 8 and 2 x 10 floor framing, wood piers, crawlspace: crawled; 20 gallon (small) and 40 gallon (1-2 people) electric and propane (quick recovery) water heater (basement and under kitchen sink base cabinet); 100-amp circuit breakers (General Electric), romex wiring, copper supply pipes, public water; awning and thermal/insulated windows, carpet, hardwood t&g and tile floors, wood cabinets, laminate and tile counters. Flagged, in Lou’s words: “Wood main beam under house right rear is sagging from termite damage”. Also noted: “Both decks have extensive water damage to planking and railing”; “Stair support column is resting on laundry shed roof, X bracing needed”; “Tree branch hitting house left rear”; “Tree branches overhanging house on front side”; “Rubber washer hoses can burst, and fittings are corroded”; “House cluttered with many items”. On the day: 72°F, cloud, light rain, damp ground, rain in the three days before; the house faces west. Not inspected that day: automatic safety controls; ceilings; insulation in attic; normal operating controls; visible electric wiring in attic. Not present in this house: chimneys, flues and vents; cooling and air handler equipment; food waste disposer; normal operating controls; operation of gfci; outlets; pantry/closet doors; presence of installed cooling source in each room; presence of installed heat source in each room; range hood; solid fuel heating devices; trash compactor; vapor retarders; ventilation fans and thermostatic controls.
2017, a colonial, about 57 years old: 12 items flagged: 6 exterior; 3 roof, chimney and attic; 3 pool. As recorded: flat roof, asphalt/fiberglass, seen from: walked, framed with 2 x 10 rafters; attic: no storage, none found ventilation; wood planking wood siding, chimney: stainless steel; wood posts foundation, 2 x 6, 2 x 8 and 2"x 10"x 2 main wood beams floor framing, wood piers (pressure treated) and locust posts, crawlspace: crawled; 75 gallon propane (quick recovery) water heater (exterior laundry closet); 200-amp circuit breakers (Cutler Hammer), romex wiring, copper supply pipes, public water, heat pump forced air; awning, sliders and thermal/insulated windows, hardwood t&g and slate floors, wood cabinets, silstone counters. Flagged, in Lou’s words: “Leaf debris is trapped under decking”; “Fireplace chimney top three sections are not secured to structure”; “Leader pipes north side are emptying near corner support column”; “Non rust proof nails staining wood siding”; “Siding needs to be water-proofed”; “Headers are putting downward pressure on door frames”; “Triangle shaped window in hallway is single pane”; “Wood frame around glass is not water-proofed or caulked”; “Stains on inside stairwell wall may be from water intrusion of window sill”; “Exterior wood stairs from ground floor to 1st floor roof, treads nailed not screwed to stringers, also needs water proofing”; “Wood posts for exterior stairs are not supported by concrete footing”; “Exterior stairs railings loose and no balusters present”; “Wood post water damaged under deck of pool, rear middle”; “Lower roof deck rail no balusters present and rail loose”; “Caution trip hazard: Lower roof one deck board middle split and sticking up”; “Upper exterior stairs stringers not secured to wall, no balusters present, side boards not screwed to upper end post”; “Upper roof railing no balusters present”; “Front boardwalk to main boardwalk trip hazard at seam”; “Caution safety item: Gates to pool area need to be self closing”; “May also be from single pane triangle window that is not caulked”. Also noted: “Propane storage bin near front boardwalk”; “Main panel in closet in east bath”; “Outside on side wall of propane enclosure”; “Caution shock hazard: Pool pump is not on a GFCI circuit”; “Jacuzzi hot tub is not on a GFCI circuit”; “Pump not bonded, does not have ground wire to ground lug”. On the day: 75°F, cloudy, damp ground, rain in the three days before; the house faces east. Not inspected that day: insulation in attic; pool liner condition; visible electric wiring in attic. Not present in this house: basement windows; burner; chimneys, flues and vents; does pool have any rescue equipment; food waste disposer; gas meter; gas/lp firelogs and fireplaces; is the pool depth marked on outside area of pool; is there a depth of at least 8 feet to allow safe diving; pool heaters; presence of installed cooling source in each room; presence of installed heat source in each room; pumps for vacuum or cleaning; range hood; roof ventilation; sump pump; trash compactor; vapor retarders; ventilation fans and thermostatic controls; walls; windows.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Suffolk County page · What an inspection costs · Schedule an inspection.