What the Wyandanch report found
The report, as Lou wrote it up.
2020, a ranch, about 80 years old: 11 items flagged: 6 exterior; 3 roof, chimney and attic; 2 kitchen. As recorded: gable roof, architectural and asphalt/fiberglass, seen from: walked, framed with 2 x 4 rafters; attic: light in attic, no storage and attic hatch in right rear bed room, soffit vents and passive ventilation; clapboard vinyl siding, chimney: metal flue pipe; poured concrete slab foundation, slab floor framing, supporting walls; hydronic heat on oil, hot water off the boiler; 100-amp circuit breakers (Westinghouse), romex wiring, copper supply pipes, public water; double-hung, thermal/insulated and sliders windows, laminated t&g floors, laminate cabinets, quartz counters. Flagged, in Lou’s words: “Lower left front roof was not re-shingled”; “No shingle caps installed on peaks”; “Left rear roof section incomplete and shingle started from top instead of from bottom”; “Tree debris all over around section of roof”; “Hole in siding right side at end of soffit”; “Hole in siding left side upper near lower roof line”; “Siding loose right rear upper”; “Right rear siding has weed wacker damage”; “In attic, holes in rear wall”; “Left rear corner trim is loose”; “Left side exterior storm door hinge is damaged, door latch is missing and door hilts saddle”; “Left side main door latch plate not installed”; “Front concrete steps and platform are cracked and holes”; “Front wood stoop railing is out of plumb”; “Front asphalt driveway needs masonry border, to prevent edges from cracking and breaking off”; “Safety Item: Dead tree branches hanging over left side of house”; “Left rear vinyl soffit cover is loose and right side vinyl soffit cover not installed”; “Rear stockade fence sections have holes and slats missing”; “Front wood stockade fence not straight and sections laying over”; “Left side large mound of leaves against foundation”. Also noted: “Right rear bedroom, window next to utility closet, upper and lower sash won't stay up and left side lock broken”; “Safety Item: Boiler utility closet does not have fire resistant sheetrock”; “Next to rear exterior wall”; “Burner is equiped with fuel shut down solenoid”; “Left side bedroom baseboard sections are too far apart to use seam kits”; “No corner kits in stalled for baseboard”; “No radiator section installed left side rear”; “Living room corner kit not installed in sheet metal”. On the day: 48°F, light rain, wet ground, rain in the three days before; the house faces north. Not inspected that day: plumbing drain and vent systems; plumbing drain, waste and vent systems; plumbing water supply and distribution systems and fixtures; plumbing water supply faucets and fixtures. Not present in this house: basement windows; clothes dryer; clothes dryer vent piping; clothes washer; columns or piers; cooling and air handler equipment; dishwasher; food waste disposer; gas meter; gas/lp firelogs and fireplaces; instant hot water; insulation under floor system; microwave cooking equipment; normal operating controls; pantry/closet doors; plumbing water faucets; presence of installed cooling source in each room; refrigerator; sewage ejection pump; solid fuel heating devices; trash compactor; vapor retarders; ventilation fans and thermostatic controls; window; windows.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Suffolk County page · What an inspection costs · Schedule an inspection.