What the Medford reports found
Lou’s two summaries flagged 12 items Repair or Replace, most for the exterior (6), roof, chimney and attic (4) and structure (2). Each report, newest first, as Lou wrote it up.
2019, a colonial, about 23 years old: 6 items flagged: 3 exterior; 2 roof, chimney and attic; 1 structure. As recorded: hip roof, architectural and asphalt/fiberglass, seen from: walked, framed with 2 x 8 rafters; attic: scuttle hole in closet and light in attic, r-30 or better insulation, soffit vents and passive ventilation; brick and clapboard vinyl and full brick siding, chimney: brick; poured concrete foundation, steel lally columns and supporting walls; hydronic heat on oil, hot water off the boiler; 200-amp circuit breakers (Square D), romex wiring, copper supply pipes, public water, air conditioner unit; casement, thermal/insulated and awning windows, hardwood t&g, carpet and tile floors, wood cabinets, granite and laminate counters. Flagged, in Lou’s words: “Roof is 23 years old, one layer”; “Roof appears to be 30 year shingle”; “May get five to seven years more depending on the weather conditions”; “Capping missing left side lower at peak corner”; “Capping cracked at peak corner left side upper”; “Leader pipe next to chimney left side needs extension pipe”; “Leader pipe left rear of garage needs pipe extension”; “Leader pipe, right rear, needs extension pipe”; “Leader pipe left front of garage needs pipe extension”; “Upper leader pipe over front entrance should be extended to lower gutter, to avoid wearing out lower roof”; “Screens missing from first floor windows”; “Right rear basement entrance wall cracked both sides from frost heaving”; “Basement entrance lower landing, leaves accumulated near drain”; “In heavy rain drain will not take water. Water will overflow into basement”; “Basement entrance railing rusted, needs scape and paint”; “No access panel to work on jacuzzi pump and motor”; “On off switch does not work”; “Basement floor cracked near boiler and water heater”. Also noted: “Chimney cap in good condition”; “Eight inch insulation between joists”; “Spider cracked, no repairs”; “Non noticed, pressured treated lumber as sill plate”; “Indirect fired off boiler”; “Water meter under basement kitchen sink”; “Main fuel oil shut off valve in basement under tank and in yard under pool heater oil tank”; “Main panel and sub panel in basement left front corner”; “Pool sub panel behind pool right rear”; “Electrical meter left front exterior wall”; “Basement baseboard radiators did not get hot, only radiant heat in basement bath got hot”; “A/C compressor is 23 years old”; “Too cold to operate A/C without damage, below 60degrees”; “Basement is not A/C cooled”; “Pumps are stored in pool shed for winter”; “Winterized, no fuel oil in tank”; “Grounding wires for pool pumps are present”. On the day: 43°F, clear, damp ground; the house faces south. Not inspected that day: do steps or ladders exist on both sides of the pool; electric lights secure; insulation under floor system; is the pool depth marked on outside area of pool; is there a depth of at least 8 feet to allow safe diving; operational condition of pool; pool heaters; pool liner condition; pumps for circulation of water; pumps for vacuum or cleaning; surface walls and floor of pool; vapor retarders; water level should be within inches from rim to allow an easier climb out. Not present in this house: burner for water heater; can fence be climbed by the use of personal items or structures against fence; does pool have any rescue equipment; gas meter; is the pool fenced; solid fuel heating devices; ventilation fans and thermostatic controls; windows.
2018, a colonial, about 23 years old: 6 items flagged: 3 exterior; 2 roof, chimney and attic; 1 structure. As recorded: hip roof, architectural and asphalt/fiberglass, seen from: walked, framed with 2 x 8 rafters; attic: scuttle hole in closet and light in attic, r-30 or better insulation, soffit vents and passive ventilation; brick and clapboard vinyl and full brick siding, chimney: brick; poured concrete foundation, steel lally columns and supporting walls; hydronic heat on oil, hot water off the boiler; 200-amp circuit breakers (Square D), romex wiring, copper supply pipes, public water, air conditioner unit; casement, thermal/insulated and awning windows, hardwood t&g, carpet and tile floors, wood cabinets, granite and laminate counters. On the day: 43°F, clear, damp ground; the house faces south. Not inspected that day: do steps or ladders exist on both sides of the pool; electric lights secure; insulation under floor system; is the pool depth marked on outside area of pool; is there a depth of at least 8 feet to allow safe diving; operational condition of pool; pool heaters; pool liner condition; pumps for circulation of water; pumps for vacuum or cleaning; surface walls and floor of pool; vapor retarders; water level should be within inches from rim to allow an easier climb out. Not present in this house: burner for water heater; can fence be climbed by the use of personal items or structures against fence; does pool have any rescue equipment; gas meter; is the pool fenced; solid fuel heating devices; ventilation fans and thermostatic controls; windows.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Suffolk County page · What an inspection costs · Schedule an inspection.