What the South Ozone Park reports found
Lou’s two summaries flagged 20 items Repair or Replace, most for the roof, chimney and attic (8), exterior (7) and kitchen (3). Each report, newest first, as Lou wrote it up.
2018, a colonial, about 93 years old: 9 items flagged: 4 roof, chimney and attic; 4 exterior; 1 garage. As recorded: gable, hip and flat roof, 3-tab fiberglass and rubber membrane, seen from: walked; attic: no storage, passive ventilation; brick and cement stucco full brick and stucco siding, chimney: brick; brick and poured concrete foundation, 3"x 8" floor framing; steam boiler heat on natural gas, 50 gallon (2-3 people) gas (quick recovery) water heater (basement, right / rear and utility area); 100-amp circuit breakers (General Electric), BX wiring, lead supply pipes, public water; double-hung and thermal/insulated windows, carpet, parqet and hardwood t&g floors, metal and wood cabinets, metal and laminate counters. Flagged, in Lou’s words: “Flat roof on house is over 20 years old”; “Roof is in need of silver paint”; “Lower roof is about 20+ years old”; “Two layers of shingle on lower roof”; “Flat roof over basement rear entrance, is pitched wrong way”; “Flashing is cracked around chimney”; “Flashing is cracked left front cheek wall”; “Old TV antenna on plumbing vent pipe”; “Left rear leader pipe needs to be extended down driveway”; “Rear basement door lock and striker do not align and door hits frame”; “Rear driveway door frame out of square and lock and striker do not align”; “Front door upper hinge is loose, causing door to hit frame”; “Front and side steps joints are eroded and bricks loose”; “Front stoop right side cheek wall is cracked”; “Front stoop right side railing post is rusted thin”; “Garage left, right and rear sides fascia board has water damage”; “Rodents getting into garage from damaged fascia”; “Right side driveway gate post is loose”; “Water damage to drop ceiling tile and plaster, second floor front bedroom”; “Stairwell plaster is cracked at corner”. Also noted: “Not enough breakers in panel to support house circuits”; “House is in cluttered condition unable to get to all outlets”; “Not enough outlets on walls throughout house”; “Caution boiler can run dry”; “Automatic water fill is not working, on auto or manual”; “Caution: Asbestos like insulation on heat pie fittings in basement”. On the day: 32°F, cloudy, damp ground, no rain in the three days before; the house faces east. Not inspected that day: insulation in attic; plumbing water faucets; visible electric wiring in attic. Not present in this house: columns or piers; cooling and air handler equipment; gas/lp firelogs and fireplaces; insulation under floor system; normal operating controls; occupant door from garage to inside home; operation of gfci; outlets & fixtures; presence of installed cooling source in each room; solid fuel heating devices; sump pump; vapor retarders; ventilation fans and thermostatic controls; windows.
2018, a colonial, about 93 years old: 11 items flagged: 4 roof, chimney and attic; 3 exterior; 3 kitchen. As recorded: gable roof, 3-tab fiberglass and asphalt/fiberglass, seen from: ladder; attic: scuttle hole over stairs, soffit vents ventilation; clapboard vinyl siding, chimney: brick and masonry stucco; masonry block foundation, 2 x 8 and 4"x 6" wood main beam floor framing, steel lally columns and supporting walls, crawlspace: crawled; hydronic heat on natural gas, 40 gallon (1-2 people) gas (quick recovery) water heater (basement left rear corner); 100-amp circuit breakers (Murray), BX wiring, copper supply pipes, public water; double-hung, thermal/insulated and sliders windows, hardwood t&g and tile floors, wood cabinets, silestone counters. Flagged, in Lou’s words: “Chimney flashing is cracked”; “No gable vent present front or rear”; “Right side gutter is full of debris”; “Both side gutters need rear down-spout and leader pipes”; “A leader pipe is required for every 25' of gutter”; “Rear basement Bilco door is rusted”; “Front stoop top limestone tread is cracked and side limestone copping are broken”; “Vine crawling on right side garage roof and on rear wall of garage”; “Garage walls are made of metal”; “Refrigerator door handle is loose”; “Front bedroom right side window locks are broken”; “Safety item: Basement steps, railing needs balusters”. Also noted: “North side of roof was covered in snow”; “Light in garage did not operate”. On the day: 50°F, clear, wet ground; the house faces east. Not inspected that day: dishwasher; insulation in attic; plumbing water faucets; roof structure and attic; visible electric wiring in attic. Not present in this house: clothes dryer; clothes dryer vent piping; clothes washer; cooling and air handler equipment; food waste disposer; gas/lp firelogs and fireplaces; presence of installed cooling source in each room; range hood; solid fuel heating devices; sump pump; trash compactor; vapor retarders; ventilation fans and thermostatic controls; windows.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Queens page · What an inspection costs · Schedule an inspection.