What the Jamaica Estates report found
The report, as Lou wrote it up.
2017, a colonial, about 67 years old: 8 items flagged: 4 exterior; 3 roof, chimney and attic; 1 garage. As recorded: gable roof, architectural, seen from: ladder, framed with 2 x 8 rafters; attic: storage and light in attic, fiberglass, below and r-19 insulation, gable vents ventilation; brick and clapboard vinyl and full brick siding, chimney: brick; poured concrete foundation, 2 x 8 floor framing, steel lally columns and supporting walls; hydronic heat on gas, 40 gallon (1-2 people) gas (quick recovery) water heater (basement and utility room); 150-amp circuit breakers (Federal Pacific and Murray), BX wiring, copper supply pipes, public water, heat pump forced air; casement, double-hung and thermal/insulated windows, hardwood t&g and tile floors, wood cabinets, granite counters. Flagged, in Lou’s words: “Snowing at time of inspection unsafe condition”; “Three layers of shingle on roof over front entrance only”; “One layer of shingle on rest of house”; “Reinspection of roof after snow melted on 3/23/2017”; “Roof is about 13 years old”; “Nail popping on front ridge at ridge vent cap”; “Nail popping at ridge cap near roof transition front section”; “Chimney flashing is cracked on upward side”; “Shingle missing and loose from left side rear middle”; “Small front roof over front entrance ridge capping mineral is worn out”; “Long section of roof draining against chimney”; “Chimney does not have stainless steel liner and no rain cap present”; “Satellite dish on front upper roof does not have sealer over anchor bolts”; “Front lower roof section gutter-guard not installed under shingle and sections missing”; “Right side rear roof section gutter-guard not installed under shingle and sections missing”; “Left side rear roof section gutter-guard not installed under shingle and sections missing”; “Left side near chimney, gutter-guard not installed under shingle and sections missing”; “Left rear upper section near window amateur vinyl siding repair”; “Left side near entrance hole in siding and panel loose”; “Driveway side door does not have weather stripping, cold draft”. Also noted: “Driveway side of front stoop platform needs pointing of cross joints”; “Front steps need handrail lower section”; “Driveway from gate to end of steps pavers not complete”; “Main water shut off in garage left front corner”; “Main panel and sub panel at top of basement steps is Federal Pacific brand”; “Main panel and disconnect switch are located in garage right front”; “Sub panel in 1st floor stairwell to basement, behind door”; “Sub panel in second floor hallway opposite bathroom”. On the day: 34°F, snow, cloudy, wet ground, rain in the three days before; the house faces NE. Not inspected that day: ceilings; flashings; floors; insulation under floor system; roof ventilation; vapor retarders. Not present in this house: gas/lp firelogs and fireplaces; presence of installed cooling source in each room; solid fuel heating devices; ventilation fans and thermostatic controls.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Queens page · What an inspection costs · Schedule an inspection.