What the Bay Ridge report found
The report, as Lou wrote it up.
2018, a colonial, about 119 years old: 9 items flagged: 2 roof, chimney and attic; 2 exterior; 2 garage. As recorded: gable roof, 3-tab fiberglass and asphalt/fiberglass, seen from: ladder and walked; attic: light in attic, no storage and walk up stairs, soffit vents and windows ventilation; clapboard and cement shingle vinyl and cement- asbestos fiber (left side) siding, chimney: brick; brick foundation, steel lally columns; hydronic heat on gas, 50 gallon (2-3 people) gas (quick recovery) water heater (basement and utility room); 100-amp circuit breakers (General Electric and Eaton), romex and BX wiring, copper supply pipes, public water, window AC; double-hung, thermal/insulated and sliders windows, hardwood t&g and tile floors, laminate cabinets, composite quartz counters. Flagged, in Lou’s words: “Right side chimney is not in use”; “This will stop up draft from old gas fireplace”; “Yankee gutters on both sides have numerous holes”; “Front covered raised concrete patio is cracked”; “Second floor deck right and rear handrails loose”; “Steel Garage, not straight pushed in on left side and rear”; “Safety Item: Basement stairs need railing with balusters 4" apart, on outside”; “Door not installed to second floor hallway”; “Door may be to large for hallway, may have to open out”; “Wall roughed up behind toilet, ceramic tile incomplete”; “Lally column footing is trip hazard”; “In basement, water valve handle in ceiling left side is hard to turn”; “Hole in sheetrock too small to get your hand around”. Also noted: “Roof is one layer, about 12 years old”; “One loose shingle left side, rear, about three feet down from rear chimney”; “Shingle are uneven and fell from line below right side chimney”; “Front lower roof need to be stripped and renewed”; “Lower rear outlet does not have current”; “Open junction box on boiler room ceiling”; “Draft going up old fireplaces in kitchen and living room”. On the day: 50°F, cloudy, light rain, wet ground, rain in the three days before; the house faces SE. Not inspected that day: ceilings; floors; insulation in attic; insulation under floor system; roof structure and attic; vapor retarders; ventilation of foundation area; visible electric wiring in attic. Not present in this house: clothes dryer; clothes dryer vent piping; clothes washer; electrical; food waste disposer; gas/lp firelogs and fireplaces; instant hot water; occupant door from garage to inside home; presence of installed cooling source in each room; range hood; solid fuel heating devices; sump pump; trash compactor; ventilation fans and thermostatic controls.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Brooklyn page · What an inspection costs · Schedule an inspection.