What the Sutton Place reports found
Lou’s three summaries flagged 6 items Repair or Replace, most for the kitchen (5) and rooms (1). Each report, newest first, as Lou wrote it up.
2022, a high rise apartment house, about 47 years old: 2 items flagged: 1 kitchen; 1 rooms. As recorded: flat roof, rubber membrane; brick full brick siding; insulated ducts, hot water off the boiler; 125-amp circuit breakers (Lexington Standard Corp), conduit wiring, public water, cooling tower; casement, thermal/insulated and tilt feature windows, hardwood t&g floors, wood cabinets, granite counters. Flagged, in Lou’s words: “Base cabinet, to right of kitchen sink, lower draw, knob loose”; “Wall cabinet to left of refrigerator, double door lower hinge loose”; “Wall around breaker panel, paint and plaster are chipped”; “Door stop rubber bumper is missing”; “This will break wall tile”. Also noted: “Exterior of building beyond scope of inspection”; “Compactor chute in common hallway of 14th floor”; “Washer does have drip pan with water alarm”; “Sub panel in apartment, on kitchen hallway wall”; “Electrical room locked on 14th floor, common hallway”; “A/C filter in all three units are fairly clean”; “Condensate dripping from coolant pipes over master bedroom air-handler and dining room air-handler”; “Condensate drain lines should be blown out at least once a year”.
2020, an apartment house, about 30 years old: nothing flagged. As recorded: flat roof, asphalt/fiberglass; metal, aluminum and granite siding; gas (quick recovery) water heater (basement water room); 100-amp circuit breakers (Gallager Switch Corp), BX wiring, public water, heat pump forced air; awning, thermal/insulated and fixed windows, hardwood t&g and tile floors, laminate, wood and glass cabinets, granite counters. Also noted: “Not allowed access to basement water room”; “Not allowed access to basement gas meter room”; “Sub panel in apartment hallway unused breakers in apartment sub panel”.
2019, about 61 years old, a co-op apartment: 4 items flagged: 4 kitchen. As recorded: forced air heat; 125-amp circuit breakers (Eaton), BX wiring, ptac units; casement and thermal/insulated windows, hardwood t&g and carpet floors, laminate cabinets, ceasar stone counters. Flagged, in Lou’s words: “Behind kitchen stove wall damaged by gas pipe”; “Microwave cabinet opening is too small for a large microwave”; “Rear stove vent panel is loose”; “Rubber hose on floor behind stove”; “Oven light does not operate, no separate switch noted”; “Three dents in refrigerator door”; “Ice tray door can't open, full of a block of ice”; “Door stop needs to be adjusted so door handle doesn't strike mirror”; “Glass shower door strikes vanity stone top”. Also noted: “Commercial unit in basement chute in hallway”; “Beyond the scope of inspection”; “Not permitted to inspect main panel in basement”; “Main panel in basement not inspected”; “Filters on all units clogged with saw dust and fiberglass insulation stuffed too close to filters, partially blocking airflow”; “Stuffing fiberglass batting near filters is problematic as fibers can become airborne and inhaled”.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: The Manhattan page · What an inspection costs · Schedule an inspection.