What the Melrose reports found
Lou’s two summaries flagged 26 items Repair or Replace, most for the roof, chimney and attic (11), exterior (9) and rooms (5). Each report, newest first, as Lou wrote it up.
2021, a town home, about 30 years old, a three-family house: 9 items flagged: 6 roof, chimney and attic; 3 exterior. As recorded: flat roof, asphalt/fiberglass, seen from: walked roof; attic: no storage, turbines and passive ventilation; cement stucco eifs siding, chimney: metal flue pipe; poured concrete foundation, 2 x 8 steel channel floor framing, supporting walls, crawlspace: crawled; non-insulated ducts, (2) 40 gallon gas (quick recovery) water heater (apartment utility closets); (2) 100-amp service panel circuit breakers (General Electric), BX wiring, copper supply pipes, public water, window AC; double-hung and thermal/insulated windows, carpet, hardwood t&g and linoleum floors, wood cabinets, laminate counters. Flagged, in Lou’s words: “Seams opening up, through out roof”; “Steel anchor rusting left front”; “Flashing is cracking at front parapet wall”; “Old rusted TV antenna on roof”; “Pull down stairs in left rear bedroom, 3rd floor”; “Roof hatch is cemented shut with roof cement and covering”; “Safety Item: Parapet wall tie back is not secured to roof joists”; “Steel tieback is digging into roofing material”; “Draft from front entrance door”; “Front concrete stoop, foundation cracked”; “Rear steel raised deck is rusting on bottom at support beams”; “Front concrete driveway is cracked and pitched toward house”; “Pitch in driveway may be contributing to water in crawl space”. Also noted: “Rubber washer hoses can burst and crimped connections are rusted”; “Shower diverter valve in faucet leaking”; “Exhaust fan does not work”; “Main breaker panel left front of 1st and 2nd floors”; “Sub panel 1st floor behind refrigerator”; “Sub panel 2nd floor kitchen”; “No filters installed in return registers”; “Filter laying on 3rd floor fan motor”. On the day: 50°F, clear, damp ground; the house faces NE. Not inspected that day: ceilings; cooling and air handler equipment; insulation in attic; normal operating controls; plumbing water faucets; roof structure and attic; visible electric wiring in attic. Not present in this house: basement windows; gas/lp firelogs and fireplaces; outlets & light fixtures; presence of installed cooling source in each room; solid fuel heating devices; sump pump; ventilation fans and thermostatic controls.
2021, a town home, about 122 years old, a three-family house: 17 items flagged: 6 exterior; 5 roof, chimney and attic; 5 rooms. As recorded: flat roof, asphalt/fiberglass, seen from: walked roof; attic: no attic access and no storage, passive ventilation; rock and mortar, brick and cement stucco full brick, stone and masonry panel siding, chimney: brick; brick foundation, 3 x 8 floor framing, supporting walls, crawlspace: no access; non-insulated ducts, hot water off the boiler; 40-amp 1st floor, 40-amp 2nd floor and 40-amp 3rd floor circuit breakers (Cutler Hammer), BX wiring, copper supply pipes, public water, window AC; double-hung and thermal/insulated windows, hardwood t&g and tile floors, wood cabinets, laminate counters. Flagged, in Lou’s words: “Roof is silver painted, over 25 years old with multiple layers”; “Left side wall flashing flap is loose”; “Left side middle of parapet wall water puddling on flashing”; “Chimney rain cap is not installed”; “Roof hatch is cement closed”; “Rear gutter has two holes in middle and water is leaking down rear wall damaging ceiling on 2nd floor and rear plaster wall on 1st floor”; “Rear gutter has hole right right of chimney, leaking dow rear wall”; “Water laying in gutter around chimney”; “Rear gutter should be connected to 5" commercial leader pipe”; “Front parapet wall, metal copping covers are rusted”; “Front facade stucco is peeling”; “Right side bituminous water proof coating is peeling”; “Right side front corner needs pointing”; “Wall cracked over left rear window 2nd floor”; “Wall cracked over left rear window 3rd floor”; “Stucco cracked over left rear window, 3rd floor”; “Rear wall discolored from water leaking from rear gutter”; “Wall cracked under 3rd floor window on fire-escape”; “Absolutely no salt on front stoop during winter. Sand is a good alternative”; “Salt is very corrosive and destroys masonry and steel”. Also noted: “Many open ground and two prong outlets throughout house”; “Main panels in 1st floor apartment entrance closet”; “Oil burner does have a fuel shut off solenoid”; “Common hallway baseboard radiator cover is off”; “Old metal duct work on ceiling in 1st floor apartment”. On the day: 79°F, clear, damp ground, rain in the three days before; the house faces SE. Not inspected that day: ceilings; insulation in attic; insulation under floor system; roof structure and attic; service entrance conductors; visible electric wiring in attic. Not present in this house: cooling and air handler equipment; gas/lp firelogs and fireplaces; outlets & light fixtures; presence of installed cooling source in each room; solid fuel heating devices; vapor retarders; ventilation fans and thermostatic controls.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: All towns · What an inspection costs · Schedule an inspection.