What the Castle Hill reports found
Lou’s two summaries flagged 6 items Repair or Replace, most for the exterior (4), garage (1) and roof, chimney and attic (1). Each report, newest first, as Lou wrote it up.
2019, a town home, about 99 years old, a two-family house: 5 items flagged: 4 exterior; 1 roof, chimney and attic. As recorded: flat roof, asphalt/fiberglass, seen from: walked; attic: no storage, passive ventilation; clapboard vinyl siding, chimney: brick; poured concrete foundation, steel lally columns; hydronic heat on natural gas, (2) 40 gallon gas (quick recovery) water heater (basement and utility room); 60-amp and (2) 100-amp service panel circuit breakers (Eaton), BX wiring, copper supply pipes, public water; double-hung, thermal/insulated and sliders windows, hardwood t&g and ceramic tile floors, not installed cabinets, not installed counters. Flagged, in Lou’s words: “Roof vents have been covered over”; “Left rear wall hole for boiler fresh air vent needs rust proof grill cover”; “Siding left rear has roofing tar stain”; “Second floor entrance, dead bolt does not line up with striker plate very difficult to open”; “Second floor balcony right rear corner, railing baluster is loose at bottom”; “Hole in concrete platform at front basement entrance”; “Floor needs a second coat of polyurethane”; “Piping needs rust proof register on right side exterior soffit”; “Cover missing from exhaust fan ceiling”. Also noted: “Roof paint will reflect heat during summer and roofing will last longer”; “Exterior, left side of front stoop”; “Basement front entrance light not installed”; “Main panels in basement cabinet left front corner”; “First floor main panel, wooden cabinet door frame hits panel door, unable to remove cover”. On the day: 29°F, clear, windy, frozen ground, no rain in the three days before; the house faces north. Not inspected that day: ceilings; floors; fuel storage and distribution systems; insulation in attic; insulation under floor system; vapor retarders; visible electric wiring in attic; walls. Not present in this house: cooling and air handler equipment; gas/lp firelogs and fireplaces; normal operating controls; presence of installed cooling source in each room; solid fuel heating devices; sump pump; ventilation fans and thermostatic controls; windows.
2013, a colonial, over 50 years old, a two-family house: 1 item flagged: 1 garage. As recorded: poured concrete foundation, poured concrete floor framing, masonry block. Flagged, in Lou’s words: “Conduit for basement light hanging down”. Also noted: “Dug out 1/3 of garage basement”; “Reinforced concrete ceiling”; “Dial Indicator mounted to bottom of W 6 x 12 Beam”; “Bottom flange depleted from rust on east side from 1/4" to 1/8" but not enough to effect any deflection in floor or steel I beam”. On the day: 45°F, clear, damp ground, no rain in the three days before; the house faces west. Not present in this house: garage ceilings.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: All towns · What an inspection costs · Schedule an inspection.