What the Pomona report found
The report, as Lou wrote it up.
2015, a ranch: 10 items flagged: 4 roof, chimney and attic; 2 exterior; 1 garage. As recorded: gable and flat roof, 3-tab fiberglass and asphalt/fiberglass, seen from: walked roof, framed with 2 x 6 rafters; attic: pull down stairs and attic hatch, below and r-19 or better insulation, gable vents, soffit vents and passive ventilation; clapboard vinyl siding, chimney: block and stone; poured concrete slab foundation, poured concrete slab floor framing, supporting walls; 50 gallon (2-3 people) electric water heater (utility room and washer dryer room); 150-amp circuit breakers (Ite), romex wiring, copper supply pipes, well or spring water, window AC; double-hung and sliders windows, hardwood t&g, carpet and tile floors, laminate cabinets, laminate counters. Flagged, in Lou’s words: “Roof over entrance to sun porch is sunken in possible plywood rotted out”; “Flat roof section over sun porch is worn out”; “Insulation in attic insufficient over right side”; “Octagon window on right side of garage attic, frame is dry rotted at bottom”; “Left side vinyl siding section is loose”; “Asphalt driveway was trenched out for sewer pipe, never repaired with new asphalt. Driveway is also heaved up in some areas and needs sealing”; “Passage door to rear yard frame is rotted at bottom”; “Left rear burner does not work”; “Parquet floor heaved up and tiles are missing in two areas”; “Right side bedrooms have asphalt tile under rugs, they are known to contain asbestos”; “Sun room, damage at corner near skylight. Checked with moisture meter readings low”; “Double door from sun room to living room hits when closing”; “Caution: Could cause wall fire. Fire place has Metal Heaterlator insert. Rust damage on right side above damper”; “Intake vents are covered”; “Wood mantel too small and loose”; “No fireplace doors present”. Also noted: “Leader pipes terminating with elbows need splash blocks under them to prevent undermining of concrete slab”; “Leader pipes terminating in 4" corrugated black hose, hoses need to be cleaned out and ends cleared from debris”; “Roof gutters need to be cleaned out of leaf debris and gutter guard installed”; “Leaf debris needs to be swept from roof to prevent clogging of drainage system”; “Front outlet near door does not work”; “Insufficient number of outlets in modular section bedrooms”; “Window does not open and track left side is broken”; “Tile floor cracked from radiant heat leak”; “Outlet has open ground and is not GFCI protected”; “Cold water does not operate at sink”; “Hot and cold do not operate at shower”; “Main shut off panel outside in meter cabinet”; “Breaker panel in mud room”; “Front right, outside in meter cabinet”; “Radiant heat did not get hot on right side of house and in living room with thermostat turned up for an hour”; “Manifold in mud room was air bound”; “Copper pipes on boiler room floor are vulnerable to damage”; “Exposed Romex Conductors in mud and boiler utility rooms are not in conduit”. On the day: 62°F, cloudy, damp ground, rain in the three days before; the house faces south. Not inspected that day: cooling and air handler equipment; fence; insulation under floor system; normal operating controls; presence of installed cooling source in each room; vapor retarders; ventilation of foundation area. Not present in this house: basement windows; burner for water heater; food waste disposer; gas/lp firelogs and fireplaces; range hood; sump pump; trash compactor; ventilation fans and thermostatic controls.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: All towns · What an inspection costs · Schedule an inspection.