What the Heartland Village report found
The report, as Lou wrote it up.
2020, a colonial, about 12 years old: 5 items flagged: 2 roof, chimney and attic; 2 exterior; 1 garage. As recorded: hip and flat roof, 3-tab fiberglass, rubber membrane and asphalt/fiberglass, seen from: walked, framed with 2 x 10 rafters; attic: pull down stairs, storage and light in attic, fiberglass and r-19 insulation, soffit vents, passive and thermostatically controlled fan ventilation; rock and mortar and clapboard vinyl and stone siding, chimney: metal flue pipe; poured concrete foundation, supporting walls; electric baseboard basement heat on electric, 50 gallon (2-3 people) gas (quick recovery) water heater (basement and closet); 100-amp circuit breakers (Murray), romex wiring, copper supply pipes, public water, air conditioner unit; casement, thermal/insulated and sliders windows, hardwood t&g and tile floors, wood cabinets, granite counters. Flagged, in Lou’s words: “Roof is 12 years old, with one layer”; “Ridge capping is raised right rear, most probably causing water stains on party wall in attic”; “Flat section of roof, right side rain trough is showing spider cracks, needs silver roof paint”; “Roofing tar can left on roof, will wear hole in flat section if not removed”; “Flat roofing material extended without support right front corner”; “Broken shingle right side rear”; “Right front short gutter, downspout needs elbow and pipe extension”; “Rear paver patio is not flat, very wavy and pitched toward house”; “Front sidewalk and driveway are pocked from salt damage”; “Safety item: Trip hazard. Driveway is cracked and raised near trough drain”; “Right rear fence wall is cracked”; “Garage concrete floor is cracked down middle and across width”; “Left front master casement window is fogged”; “Safety item: In attic, no fire-resistant sheetrock over furnace”. Also noted: “Gas shut off cock in wall behind dryer”; “Has ice maker and cold water connection”; “Safety item: In attic, no fire- resistant sheetrock over furnace”; “Shower diverter valve in tub faucet leaks”; “Water heater is 12 years old, near end of life”; “Meta round duct in attic is not insulated”; “Round flex duct slipping off main duct connector under evap unit”. On the day: 21°F, clear, cold, frozen ground, no rain in the three days before; the house faces SE. Not inspected that day: ceilings; floors; insulation under floor system; plumbing water faucets; ventilation fans and thermostatic controls. Not present in this house: basement windows; food waste disposer; gas/lp firelogs and fireplaces; range hood; sewage ejection pump; solid fuel heating devices; trash compactor; vapor retarders; windows.
“Flagged” is HomeGauge’s Repair or Replace mark, not a verdict on the house. See a complete report.
Related: All towns · What an inspection costs · Schedule an inspection.